Product Description
Structure
Features
1. Refrigeration system: With low noise totally enclosed compressor, air cooled with cooling speed, temperature stability is strong, etc.
2. Control system: Latest proprietary software research and development of homemade temperature control technology, with high standards of Pt100 and all imports of electronic parts, etc.
3. Circulating system: Consists of inner and outer loop irfpa outer loop slot can be constant temperature liquid, can establish the temperature field, also can be used as cold source to guide groove is cooling liquid into closed experimental container cooling, inner loop can make the liquid in the tank temperature was uniform and stable.
4. Protection system: Refrigeration is overheated, over-current protection, call control system has over temperature alarm, can be set over temperature alarm temperature, the temperature of the upper and lower limits can cut off the load automatically when over temperature, and other functions.
5. High-end LCD control instrument, simple operation, temperature stability is strong, P.I.D can automatically search or artificial adjustment
6.Accurate temperature correction function can reach 0.01 ℃, temperature fluctuation degree of up to + / - 0.02 ℃ ~ + / - 0.05 ℃ (depending on the type).
Technical Parameters
For Glass Reactor |
Item No |
Temperature range(℃) |
Resolution (±℃) |
Tank capacity (L) |
Circulation Flow (L/min) |
Heating Power (KW) |
Dimension(mm) LxWxH |
|
RT~200 |
||||||||
1L 2L 3L |
TG-2005 |
RT~200 |
0.1 |
5 |
8 |
1.6 |
240x370x400 |
|
3L 5L |
TG-2010 |
RT~200 |
0.1 |
10 |
15 |
2.0 |
320x370x470 |
|
10L |
TG-2015 |
RT~200 |
0.1 |
15 |
15 |
3.0 |
320x370x570 |
|
10L |
TG-2020 |
RT~200 |
0.1 |
20 |
15 |
3.5 |
320x370x570 |
|
20L |
TG-2030 |
RT~200 |
0.1 |
30 |
15 |
3.8 |
320x370x570 |
|
30L |
TG-2050 |
RT~200 |
0.1 |
50 |
15 |
4.4 |
320x370x570 |
|
50L 80L 100L |
TG-20100 |
RT~200 |
0.1 |
50 |
15 |
6.5 |
400x600x600 |
|
RT~300 |
||||||||
1L 2L |
TG-3005 |
RT~300 |
0.1 |
5 |
8 |
1.6 |
240x370x400 |
|
3L 5L |
TG-3010 |
RT~300 |
0.1 |
10 |
15 |
2.0 |
320x370x470 |
|
|
TG-3015 |
RT~300 |
0.1 |
15 |
15 |
3.0 |
320x370x570 |
|
10L |
TG-3020 |
RT~300 |
0.1 |
20 |
15 |
3.5 |
320x370x570 |
|
20L |
TG-3030 |
RT~300 |
0.1 |
30 |
15 |
3.8 |
320x370x570 |
|
20L |
TG-3050 |
RT~300 |
0.1 |
50 |
15 |
4.4 |
320x370x570 |
|
30L 50L |
TG-30100 |
RT~300 |
0.1 |
50 |
15 |
6.5 |
400x600x600 |
Precautions for use
1.Before using slot should be in liquid medium. (note: liquid not contain acid alkali).
2.The total power of the power is to be greater than or equal to the instrument, the power must have a good "grounding" device. Using the voltage will be subject to technical parameter table.
3.Device should be placed in ventilated dry place, back and sides leave obstacles 300 mm distance。
4.After use, all switch off and unplug the power plug.