• Refrigerated heating circulators

  • Refrigerated heating circulators

  • Refrigerated heating circulators

  • Refrigerated heating circulators

  • Refrigerated heating circulators

Refrigerated heating circulators

A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature. The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circul

Product Description

Application description

1.Reactor Systems Autoclaves

2.Pilot Systems

3.Mini Plant Systems

4.Scale up for Operational Development

5.Double wall reactors

6.Advanced-Flow Reactors

7.Distillation Systems

8.Material Testing

9.Combinational Chemistry

10.Semiconductor Industry

11.Vacuum Chambers

 

Advantages

1.Working temperatures from -100℃ to +350℃

2.Previously unachievable performance

3.Intelligent temperature control

4.Maximum process stability and reproducibility 

5.Adopt plate heat exchanger, Pipeline heating, the fastest heating and cooling rates

6.High cooling power from 0.5 to 1200kW

7.Large temperature range without fluid change

8. Closed system, extend thermal fluid lifetime

9.Incredibly compact

10.7-inch, 10-inch color TFT touch screen display

11.Comprehensive warning and safety functions

12.Rapid cooling down from high temperature (from 300 ℃)·

13.Use magnetic drive pump, solve the circulation pump leakage.

 

Technical Parameters

Model

SUNDI-320

SUNDI-420W

SUNDI-430W

Temperature range °C

-30°C~180°C

-45°C~180°C

-45°C~180°C

Control Mode

Feed forward PID + Our special dynamic control calculation, PLC controller

Temp. control

Option: process temperature control or jacket oil temperature control

Temp. difference

Set or control the temperature difference between jacket oil and raw material process

Program Editor

20 programs, each program can edit 45 steps.

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium :PT100  Raw material process:PT100

Temp. accuracy

±1°C

±1°C

±1°C

Heating power

2kW

2kW

3kW

Cooling capacity

180°C

l.5kW

1.8kW

3kW

50°C

1.5kW

1.8kW

3kW

0°C

1.5kW

1.8kW

3kW

-5°C

0.9kW

1.2kW

2kW

-20°C

0.6kW

1kW

1.5kW

-35°C

\

0.3kW

0.5kW

Circulation pump

Max10L/min 0.8bar

Max10L/min 0.8bar

Max20L/min 2bar

Compressor

Embraco

Embraco

France

Expansion valve

Danfoss

Danfoss

Danfoss

Evaporator

KAORI Plate heat exchanger

Operation Panel

7-inch color touch screen controller,temperature curve record.data export to excel format.

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

Closed circulation system

The whole system is full closed circulation,there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running.The system will supplement oil automatically at low temperature.

Refrigerant

R404A

R404A

R404A

Connection size

DN-15 or M24*1.5

DN-15 or M24*1.5

DN-15 or M24*1.5

Water-cooled type W (cooling water at 20°C)

\

450L/H

1.5bar~4bar

550L/H

1 .5bar~4bar

Power

AC 220V 50HZ 2.9kW(max)

AC 220V 50HZ 3.3kW(max)

AC 380V 50HZ 4.5kW(max)

Case material

SUS 304

SUS 304

SUS 304

Optional

Optional Ethernet interface , configure PC operating software

Optional

Optional outside touch screen display controller (separated),the communication line distance is 10 meter.

Optional power

Optional power 100V 50HZ single-phase, 110V 60HZ single-phase, 230V 60HZ single-phase, 220V 60HZ three-phase, 440V~480V 60HZ three-phase

Note

-10°C~200°C, -25°C~200°C, -25°C~300°C, -45°C~250°C, -50°C~250°C, -60°C~200°C, -60°C~250°C, -70°C~250°C, -80°C~250°C, -90°C~250°C, -100°C~100°C, -90°C~250°C, -25°C~200°C, -40°C~200°C

 

The HR series all look the same, but the model parameters are different, the content is as follows:

 

Description

The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃.

The cycle is closed,there is no oil mist at high temperature and no water vapor at low temperature. Wide working temperature range of heat transfer oil. The entire circulation system without use of mechanical and electric valve.

 

Features

1.Wide working temperature range with cooling and heating function, temperature range:-25~200°C.

2.With 2pcs of LED display controller, can show the setting temperature& actual value, and alarm value for over temperature.

3.Efficient fast, simple topping up liquid.

4.Ensure fast cooling at high temperature and can achieve 200℃~-25℃ temperature control continuously.

5.The cycle system is closed, there is no oil mist and water vapor happend, so as to assure the lab safety and heat transfer fluid lifetime.

6.Use copeland brand compressor, circulation pump, stable performance and reliable quality.

7.Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

8.Use the same kind of heat conducting in the whole heating-cooling cycle when control heat conducting medium temperature.

9.High-lift design and meet the long-distance transportation of heat conducting medium.

 

Technical Parameters

Model

HR-25 N

HR-35 N

HR-50 N

HR-70 N

HR-100 N

HR-150 N

Temperature range °C

-25°C~200°C

Controller

PID adaptive controller

Temp. control

Heat-conducting medium outlet temp.control

Communication protocol

MODBUS RTU Protocol, RS 485 Interface

Temperature feedback

Heat-conducting medium temperature feedback PT100

Temp, accuracy

±0.5°C

±0.5°C

±0.5 °C

±0.5°C

±0.5 °C

±0.5°C

Heating power

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

Cooling capacity

200°C

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

100°C

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

20°C

2.5kW

3.5kW

5.5kW

7kW

10kW

15kW

-5°C

2kW

3kW

4.5kW

6.6kW

8kW

12kW

-20°C

1kW

1.8kW

2.8kW

3.8kW

4.6kW

7kW

Circulation pump

Max25L/min 2bar

Max35L/min 2bar

Max35L/min 2bar

Max35L/min 2bar

Max50L/min

2 bar

Max50L/min

2 bar

Tank volume

8L

13L

15L

18L

22L

25L

Compressor

Copeland

Copeland

Copeland

Copeland

Copeland

Copeland

Evaporator

Plate heat exchanger

Operation Panel

Display setting temperature and testing temperature; outlet and inlet temperature, 7-inch color touch screen

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

Closed circulation system

The whole system is full closed circulation,there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running.The system will supplement oil automatically at low temperature.

Refrigerant

R-404A

R-404A

R-404A

R-404A

R-404A

R-404A

Connection size

DN15

DN20

DN20

DN20

DN20

DN20

Power

AC 220V 50HZ 4kW(max)

AC 380V 50HZ 5.5kW(max)

AC 380V 50HZ 7.5kW(max)

AC 380V 50HZ 10kW(max)

AC 380V 50HZ 14kW(max)

AC 380V 50HZ 21kW(max)

Case material

Cold rolled steel

Optional

Optional 7-inch color touch screen controller,temperature curve record,data export to excel format.

Optional

SUS304 case material

Optional power

220V 60HZ three-phase, 440V ~ 430V 60HZ three-phase

 

  • wechat