Product Description
Advantages description
1.DL series of supporting the use of water can be used instead of condensation, especially for low boiling point or heat-sensitive materials evaporate when condensed water. For high temperature or lack of water resources to achieve water-saving areas, but also to ensure that the cooling equipment is rapidly cooling needs.
2.Work can be placed in the cold tank containing biochemical reagents or samples of a variety of containers directly under low temperature thermostat experiments and testing.
3.Large-screen LCD display, software automatically control the cooling system to open, convenient and quick.
4.Efficient air-cooled fully enclosed compressor refrigeration, with delay, overheating, over-current and other multiple protection.
5.The circulating pump can cool the coolant in the tank, cool or cool the test container or set up a second constant temperature field.
6.The software can correct the temperature measurement deviation, the temperature is accurate up to 0.1 ℃.
Technical Parameters
Model |
Temperature range (℃) |
Digital resolution (℃) |
Accuracy (℃) |
Working tank volume (L) |
Cooling capacity (W) |
Max column height (m) |
Circular flow (L/min) |
DL-1005 |
-10-RT |
0.1 |
±0.5 |
5 |
350 |
4 |
15 |
DL-2005 |
-20-RT |
0.1 |
±0.5 |
5 |
180 |
4 |
15 |
DL-3005 |
-30-RT |
0.1 |
±0.5 |
5 |
150 |
4 |
15 |
DL-4005 |
-40-RT |
0.1 |
±0.5 |
5 |
200 |
4 |
15 |
DL-6005 |
-60-RT |
0.1 |
±2 |
5 |
1910~300 |
4 |
15 |
DL-7005 |
-70-RT |
0.1 |
±2 |
5 |
2020~250 |
4 |
15 |
DL-8005 |
-80-RT |
0.1 |
±2 |
5 |
2100~210 |
4 |
15 |
DL-1010 |
-10-RT |
0.1 |
±0.5 |
10 |
500 |
4 |
15 |
DL-1510 |
-15-RT |
0.1 |
±0.5 |
10 |
600 |
4 |
15 |
DL-2010 |
-20-RT |
0.1 |
±0.5 |
10 |
1150 |
4 |
15 |
DL-3010 |
-30-RT |
0.1 |
±0.5 |
10 |
300 |
4 |
15 |
DL-4010 |
-40-RT |
0.1 |
±0.5 |
10 |
400 |
4 |
15 |
DL-6010 |
-60-RT |
0.1 |
±2 |
10 |
2750~300 |
4 |
15 |
DL-7010 |
-70-RT |
0.1 |
±2 |
10 |
2870~280 |
4 |
15 |
DL-8010 |
-80-RT |
0.1 |
±2 |
10 |
2900~230 |
4 |
15 |
DL-1015 |
-10-RT |
0.1 |
±0.5 |
15 |
800 |
4 |
15 |
DL-2015 |
-20-RT |
0.1 |
±0.5 |
15 |
700 |
4 |
15 |
DL-3015 |
-30-RT |
0.1 |
±0.5 |
15 |
1000 |
4 |
15 |
DL-4015 |
-40-RT |
0.1 |
±0.5 |
15 |
600 |
4 |
15 |
DL-6015 |
-60-RT |
0.1 |
±2 |
15 |
2980~570 |
4 |
15 |
DL-7015 |
-70-RT |
0.1 |
±2 |
15 |
3250~480 |
4 |
15 |
DL-8015 |
-80-RT |
0.1 |
±2 |
15 |
3500~320 |
4 |
15 |
DL-1020 |
-10-RT |
0.1 |
±0.5 |
20 |
1000 |
4 |
15 |
DL-2020 |
-20-RT |
0.1 |
±0.5 |
20 |
1300 |
4 |
15 |
DL-3020 |
-30-RT |
0.1 |
±0.5 |
20 |
1400 |
4 |
15 |
DL-4020 |
-40-RT |
0.1 |
±0.5 |
20 |
800 |
4 |
15 |
DL-6020 |
-60-RT |
0.1 |
±2 |
20 |
4120~510 |
4 |
15 |
DL-7020 |
-70-RT |
0.1 |
±2 |
20 |
4380~420 |
4 |
15 |
DL-8020 |
-80-RT |
0.1 |
±2 |
20 |
4530~360 |
4 |
15 |
DL-1030 |
-10-RT |
0.1 |
±0.5 |
30 |
2300 |
4 |
15 |
DL-2030 |
-20-RT |
0.1 |
±0.5 |
30 |
1800 |
4 |
15 |
DL-3030 |
-30-RT |
0.1 |
±0.5 |
30 |
1000 |
4 |
15 |
DL-4030 |
-40-RT |
0.1 |
±0.5 |
30 |
1000 |
4 |
15 |
DL-6030 |
-60-RT |
0.1 |
±2 |
30 |
4330~680 |
4 |
15 |
DL-7030 |
-70-RT |
0.1 |
±2 |
30 |
4520~570 |
4 |
15 |
DL-8030 |
-80-RT |
0.1 |
±2 |
30 |
4679~440 |
4 |
15 |
DL-1050 |
-10-RT |
0.1 |
±0.5 |
50 |
2500 |
4 |
15 |
DL-2050 |
-20-RT |
0.1 |
±0.5 |
50 |
4000 |
4 |
15 |
DL-3050 |
-30-RT |
0.1 |
±0.5 |
50 |
2800 |
4 |
15 |
DL-4050 |
-40-RT |
0.1 |
±0.5 |
50 |
1500 |
4 |
15 |
DL-6050 |
-60-RT |
0.1 |
±2 |
50 |
10570~1600 |
4 |
15 |
DL-7050 |
-70-RT |
0.1 |
±2 |
50 |
10800~1480 |
4 |
15 |
DL-8050 |
-80-RT |
0.1 |
±2 |
50 |
11200~1260 |
4 |
15 |
Precautions for use
1.Before using slot should be in liquid medium. (note: liquid not contain acid alkali).
2.The total power of the power is to be greater than or equal to the instrument, the power must have a good "grounding" device. Using the voltage will be subject to technical parameter table.
3.Device should be placed in ventilated dry place, back and sides leave obstacles 300 mm distance.
4.After use, all switch off and unplug the power plug.